T/369(1) –
ADVANCE AUTHORITY TO PASS A DEFECTIVE RECEPTION SIGNAL
Ø
Issued
at a nominated Station to pass a defective reception signal at ON at a station
in advance.
Ø
PHS is exhibited at the foot of the defective
signal. If PHS is not exhibited at the foot of the defective signal, LP shall
stop the train.
Ø
On
getting PHS, LP shall pass the signal at a speed not exceeding 15 kmph.
Ø
Nominated
station means the last stopping station for Express and Passenger trains as per
WTT and station immediately in rear for Goods and light engines.
Ø
This
shall not be issued if
o The
signal has failed in the OFF position.
o In
colour light area, during power failure including backup power.
o If
calling on signal or SPT is provided and is in working order.
o SM before
authorizing the nominated station to issue this authority shall satisfy the
conditions for taking OFF of defective signal including signal overlap before
granting LC.
Ø
This
shall not be used in automatic and CTC area.