- Secure Control Stand & Loco with skids & hand brake tightly after clearing Fouling Mark.
- Check & record water & oil balances & check repair book for any remark for not to shut down.
- Fill the Repair book completely with remarks.
- Ensure RF is Off & Battery charging is normal.
- Press EFCO and shutdown the loco.
- Keep computer breaker ON in both cabs & TURBO breaker ON in cab 1.
- Switch OFF all other breakers in both cabs.
- Slider switches in both C/stands to be switched OFF, Open Battery knife switch.
- Record date, time & reason for shut down and Hand over RH to concerned person.
P.No.9731647155 & Rly No.59513 CMS.No.080-28451437 & Rly No.59445 Office No.59448, 080-28457080 CCRC-9731647238