Search This Blog

Thursday, 24 August 2017

Power Ground


DID will show “ALARM - NO LOAD - GROUND RELAY POWER”.
Secure Control Stand & press the Reset button.
Check power circuit equipments for abnormal indications like temperature, burning smell, smoke or fire.
If any TM having abnormal indication, disable TM or Truck
If GR Trips Repeatedly 3 times within 10 minutes
DID shows “ALARM - NO LOAD - GROUND RELAY – LOCK OUT”
If no abnormality, disable TM or truck one by one and try
Even after trying with all TMs or both Truck disabling, Trouble not rectified - Contact PRC / Shed
Work With 60 % Load (Freight)
Coaching Train – No Reduction In Load

Ground Protection in Medha HHP Loco
To reset the fault, Secure Control Stand and wait for 15 seconds.
Auto reset is permitted for 3 times in 1 Hr.
4th Time GR Lock Out occurs
Disable TMs and try

Note:
No Load - GR Cut out Message
Ensure GRNTCO is in ON position & sealed
Check GRNTCO wire connection behind breaker panel
Try by Recycling Computer Breaker
Try by DIO card swapping in EMD Locos

Contact shed

Leave sanctioned list

THE FOLLOWING EMPLOYEES LEAVE HAS BEEN SANCTIONED/REGRETTED BY DEE/CCRC/KJM   (23.05.2019) S.N   Name of t...