Medha Microprocessor Loco fault resetting


Manual Fault Resetting - Ver. 2
Bring TH to Idle
Wait for 15 seconds
Fault may reset automatically
If fault not reset,
Select Main menu
Select Faults
Select clear Active faults
DID shows “Press 0 and ENTER key to clear the Fault”
Fault will be displayed – press 0 & Enter
Press down arrow to select next fault, then clear
If password is asked – enter “12345” & try
If DID shows wrong password – contact shed

Manual Fault Resetting - Ver. 3
Bring TH to Idle
Wait for 15 seconds
Fault may reset automatically
If fault not reset,
Select Main menu
Select Faults
Select clear Active faults
DID shows fault based on priority & “Clear” above F4
Press F4 to Clear
Next fault will be displayed – clear all faults
If password is asked – enter “12345” & try
If DID shows wrong password – contact shed

If fault not recovered, in both versions
Switch OFF MPCB
Wait for 60 seconds
Switch ON MPCB
If fault is not recovered,
Shutdown the Loco
Switch OFF all breakers
Wait for 2 minutes
Switch ON all breakers
Re-crank the loco and try
Note down fault code & message and contact shed for advice.