Trouble shooting for Engine not Cranking Common for all Mcp Locos


Reasons
Remedies
No / Less FOP
Trouble shoot / contact shed
Any breaker tripped
Reset
ECS not in Idle (Start in GE Mcp)
Keep in Idle (Start)
Start button defect
Try 2 – 3 times.
MUSD not in Run
Keep in Run
LLOB Tripped
Reset
Cranking contactor welded
Check I/Ls and main contact. Separate if welded
Cranking contactors defective
Check terminals, mechanical binding & coil condition
Mcp restrictions
Trouble shoot as per message
Weak batteries
Contact shed
AG & EG defects
Contact shed
Mcp / Sensor defect
Contact Shed

Trouble shooting for Engine not Cranking Medha Mcp Loco
Reasons
Remedies
Start button defect
Use DID Soft key in Ver. 3
AGPR & EXPR stuck closed
Manually release the I/Ls
CKC defective
Check terminals, mechanical binding & coil condition

Trouble shooting for Engine not Cranking GE Mcp Loco
Reasons
Remedies
FPR N/o I/L defective
Attend I/L
EST Start contact defective
Try 2 – 3 times.
CGR N/c I/L defective
Attend I/L
AGFR & EXFR stuck closed
Manually release the I/Ls
CKC 1, 2, 3 defective
Check terminals, mechanical binding & coil condition

Trouble shooting for Engine not Cranking Siemens Mcp Loco

Reasons
Remedies
CKR 1, 2, 3  defective
Check terminals, mechanical binding, coil condition & I/Ls

Trouble shooting for Engine Cranking but not Firing
Reasons
Remedies
No Fuel oil pressure
Troubleshoot
No oil in WW Governor
Contact shed
Gov. linkage with fuel control shaft uncoupled
Check and connect.
MCBG Power Breaker OFF / Tripped (MCBG alone Blank)
Switch ON / Reset
MCBG Ack. button not pressed before cranking / After Shut down
Press Ack. Button on MCBG Control Unit
Cable disconnected in MCBG Control unit Actuator
Ensure Proper connection
Low water level
Ensure Sufficient Water level
Water level sensor defective
Ensure water level.
Switch on emergency bypass switch / Remove fuse in Electronic water level indicator.
OSTA tripped
Reset properly
LLOB tripped
Reset LLOB
MUSD not in RUN
Keep MUSD in RUN
Water Contamination in Fuel oil
Inform PRC / Shed
Weak batteries.
Press Gov. Linkage while cranking & try
ESS / DSS uncoupled / defective
Couple / Switch on bypass switch if provided