Search This Blog

Thursday, 6 July 2017

Trouble shooting for Throttle not Responding


Reasons
Remedies
Mcp Restriction message
Troubleshoot
MCB OFF / Tripped (ERS in GE)
Switch ON / Reset
DMR not energizing due to MCH / TH not in Idle / defect
Keep in Idle / Check MCH coupler / Change C/stand. Energize DMR manually
PCS2 operated
  •  Less BP pressure
  •  PCS2 COC closed
  •  PCS 2 defect

§  Ensure Sufficient BP Pressure.
§  Open
§  Switch ON Eme. DMR / PCS2 Switch / Short PCS2 terminals
DMR defects (PCR in GE)
  •  Terminal disconnected
  •  Coil open circuit or I/Ls defect

Secure
Switch ON Eme. DMR / Contact shed
DMR energizing in IDLE but de – energizes  while moving TH to 1st Notch
Check DMR I/Ls
If unsuccessful – Switch ON Eme. DMR
ECS not in RUN
Keep in RUN. Use DID soft key in Ver. 3
Amphenol plug uncoupled (WW gov.)
Re-Connect
Power Ground
Reset
Generator Field Overload
Reset
VCD / AFL operated / defective
Reset / contact shed
BKT not in motoring
Set manually
Rectifier fuse blown
Contact shed
Mcp / BP sensor defect
Contact shed
ABCR de-energized (GE Mcp)
Check terminals / contact shed


Leave sanctioned list

THE FOLLOWING EMPLOYEES LEAVE HAS BEEN SANCTIONED/REGRETTED BY DEE/CCRC/KJM   (23.05.2019) S.N   Name of t...