Trouble
shooting for Load meter not Responding – Loco Not Moving
Reasons
|
Remedies
|
Throttle also not
responding
|
Troubleshoot for TH
not responding
|
Mcp Restriction
message
|
Troubleshoot
|
Any breaker tripped
|
Reset
|
MFPB tripped in any
C/stand.
|
Reset (LAM will not
respond and engine may shutdown later)
|
ECS not in RUN
position.
|
Keep in RUN / Use
Soft key in DID in Ver.3
|
RH not in direction
|
Keep in required
direction or Try from other C/stand
|
Other C/s RH not in
Neutral / TL 8 & TL 0 High message
|
Keep in Neutral or try
from other C/stand
|
MCH not in Notch
position.
|
Ensure in Notches or
Try from other C/stand
|
GF switch OFF in
C/stand
|
Keep in ON position
|
Cranking contactors
welded
|
Separate
|
BKT not in motoring
position.
|
Check terminals /
Set Manually
Clean BKT Aux.
Contacts
|
Reverser not in
direction
|
Check terminals /
Set Manually
Clean Reverser Aux.
Contacts
|
EPPCs not picking up
|
Ensure Control Air
pressure
|
GFC not picking up
|
Check terminals /
Clean the I/Ls
Switch On Eme. GF
switch if avl. Pack GFC
|
Note: Before packing GFC, ensure
cranking contactors open and BKT in motoring. After packing acknowledge DID
GFC stuck closed fault message
|
|
Power ground
|
Troubleshoot.
After opening GRCO1
in GE ensure ATK & ATN shorted
|
EG, TA & RB
defects
|
Inform PRC / Shed
|
Master control
handle coupler slack / disconnected
|
Secure it / Try from
other C/stand
|
Tacho gen. / ESS /
DSS defects
|
Check connections.
Contact shed
|
EXPR / EXFR not
energizing
|
Troubleshoot /
Contact shed
|
CKR2 not
de-energizing (Siemens)
|
Troubleshoot /
Contact shed
|
Mcp / Sensor defects
|
Recycle Mcp breaker
with 2 minutes time interval / Contact shed
|