Siemens Fault Resetting

Siemens – KM Direkt
Bring TH to Idle
Wait for 15 seconds
Fault may reset automatically
If fault not reset - Troubleshoot
Check DID by pressing F1 – F1 – List of faults will be displayed
Inactive fault is indicated by empty circle
Active fault is indicated by filled circle

Siemens – PLC / Simcontrol
Bring TH to Idle
Wait for 15 seconds
Fault may reset automatically
If fault not reset
Check DID Red LED
Non Acknowledged active fault is indicated by LED blinking
Acknowledged active fault is indicated by LED glowing continuously
Troubleshoot as per fault message
Inactive fault – LED is off

If fault not recovered, in both types
Switch OFF F1 to F8 (F1 to F4)
Wait for 2 minutes
Switch ON F8 to F1 (F4 to F1)
If fault is not recovered,
Shutdown the Loco
Switch OFF all breakers
Wait for 2 minutes
Switch ON all breakers
Re-crank the loco and try

Note down fault code & message and contact shed for advice. 