Reasons
|
Remedies
|
Defects in Fuel Oil
System
|
Rectify it
|
BAP Pipeline of Gov.
/ Gauge / Sensor leaking
|
Try to re-connect
|
Abnormal sound from
Turbo
|
Shutdown loco &
inform shed
|
Exhaust gas leakages
|
Inform Shed
|
TE Limit Switch in
Limit position
|
Keep in Normal
|
Power setter switch
enabled
|
Keep in Normal
|
BAP sensor defect /
continuous BAP Load Control message
|
Keep BAP bypass
switch in Bypass position in MCBG control unit
|
Fuel Rack Position (FRP)
sensor defect
|
Disconnect FRP
connection & try
|
Fuel control shaft
Cross over link uncoupled
|
Shutdown & try to reconnect or contact shed
|
FIP Locked
|
Check for remarks /
contact shed
|
TM isolated
|
Check for remarks /
contact shed
|
EPPC not picking up
|
Check wire & Air
pipe connection
|
Note: Trouble shoot as per message, if restrictions
imposed by Microprocessor due to
- Hot Engine
- High TM temperature
- Rectifier Fuse Blown / High temperature
- Earth Leakage in power circuit