Trouble shooting for Continuous Hot Engine Alarm



Reasons
Remedies
Continuous working in Higher notches,
high ambient temperature
Perform Fast air pumping
Radiator room door open
Close the door and secure it.
Insufficient water level
Add water consulting PRC / shed
Lube oil contamination in water (Oil traces will be visible in expansion tank)
Inform shed
Pump defect 
Inform shed
Radiator fan not working
Defective EWT / LOT / sensor, R1 and R2 (ECR1 & ECR2 in GE Mcp)
Switch ON ERF/RFCB & Ensure RF is working
ECC coil  short circuited (FPB will trip)
Inform shed.
Loose or open ECC terminal connections in terminal box
Check and secure
Dirty slip rings
Clean with dry cloth.
Defective carbon brush such as sticky, worn out, broken, pig tail cut, less spring tension, etc
If so clean or replace and secure properly
Spider shifted



Inform PRC / Shed
Koopers coupling worked out (outer drum will not rotate)
Defective right angle gearbox
Universal coupling worked out
Shaft bearing seized
Radiator Fan Blade Broken