ELECTRIFIED SECTION General instructions


General instructions

Ø 110 or 132 Power supply from Electricity Board is received at Traction Sub-Station in KV.
Ø Power supply from Electricity Board is received in Three Phase.
Ø At Traction Sub – Station, the power supply is step down to 25 K.V.
Ø This 25 KV power supply is given to Feeding Post.
Ø Feeding post means Supply control post, where the incoming feeder lines from the grid sub- station are temporarily terminated.
Ø Power is supplied to Over Head Equipments in Single Phase.
Ø Power supply from adjacent Feeding Post is given in different Phases.
Ø To separate the two Phases at the meeting point, a Neutral Section is provided.
Ø A separate SWR, pertaining to 25 K.V. Traction, signed by DSO and DEE/ TRD, shall be issued.
Ø Power Block means blocking of a section of line to electric traffic only.



Neutral Section:
Ø  It means a short section of insulated and dead OHE, which separates the areas fed by adjacent sub-stations or feeding posts.
Ø  Before entering Neutral Section, LP shall switch off power supply and after the engine clears Neutral section, LP shall switch on power supply.
Ø  While approaching Neutral Section, the speed of trains shall not be less than 30 kmph.
Ø  Warning Boards are provided at 500M and 250M to inform LP that he is approaching a Neutral Section.
Ø  Warning Boards are also provided to inform LP where to switch off power supply and to switch on power supply.

 Temporary Neutral Section:
Ø  If temporary speed restriction of less than 30 kmph to be imposed within 1 Km on either side of Neutral section, the Engineering official shall advise SMs at both ends.
Ø  SMs shall advise Section Controller and TPC.
Ø  TPC shall arrange to energize the Neutral section and to provide a temporary Neutral Section, where necessary.
Ø  Caution orders shall be issued to LP that the original Neutral Section is energized and the location of temporary Neutral Section and also the locations where to lower and raise pantograph.
Ø  Warning boards shall be provided if temporary Neutral Section arrangement continues for more than 24 Hours.