Trouble shooting for Battery Discharging / AG no output


Indication: BCA shows Discharge side & AG Fail lamp glows
Reasons
Remedies
Mcp fault Message
Trouble shoot / contact shed
AGFB tripped / OFF (Medha)

Reset/Switch ON
AFCB / CCB / LCCB tripped / OFF (GE)
F7/F3 tripped/OFF (Siemens)
AG Protection Relay not energized  (AGPR/AGFR)
Check terminals, mechanical binding, coil & I/Ls
Cranking contactor welded
Separate it
CKR2 I/Ls defective
Ensure Relay de energized. Attend I/Ls
Mcp / Sensor defects
Contact shed
Note: Loco can be worked with Battery power for 4 to 5 hours duly informing shed with minimum lighting usage

Trouble shooting for Miscellaneous Troubles

Indication
Reason / Remedies
BCA showing more than 30 Amps charging side
Due to weak battery
Open BS and work with AG supply.
Do not shut down the loco & inform shed / PRC
BCA overcharging on notches
AG excitation system malfunction
Switch Off AGFB / AFCB / F7 & wok with BA supply
Do not shut down the loco & inform shed / PRC
BCA showing Zero
Ensure BS closed, MB1 ON
Check Battery cables
Inform shed / PRC