If a
Distant/Warner on a separate post has failed in the “OFF” aspect, and cannot be
kept at ‘ON’. -
Ø A stop hand signal shall be exhibited at the foot of the signal.
Ø During night, the light shall be extinguished.
Ø SM in rear shall be informed to issue Caution order to the Loco pilot to
stop at the foot of the defective Distant/ Warner.
Ø After the train has been brought to a stop, the same shall be hand
signaled.
Ø If the permissive signal failed in the ON aspect no specific authority is
required to pass it.
No
light in a color light signal.
Ø Stop the train in rear of the signal.
Ø Treat as if the signal is at ON.
Ø For permissive signal, ensure (P) marker and proceed cautiously and be
prepared to stop at the foot of the home signal.
Ø For Home signal SM shall issue T/369 3(b) and receive the train.
Ø Issue of T/369 (1)
is strictly prohibited in this case. GDR shall report and record it as per the
procedure.